PRAESENSA Getting started | en 21
Bosch Security Systems B.V. Configuration manual 2020-09 | V1.20 | PRAESENSA 1.20
The call station display indicates the upload process as long the upload process of
the device runs.
7. Repeat the previous steps 4‑6 for all other connected network devices:
The firmware upload is successfully if no fault messages are generated.
8. Continue with
Logon the application, page 35
.
9. If the upload was not successfully completed (the State column indicates "Failed" with a
red color bar) and/or fault messages are generated, proceed as follows:
First check the current network device and downloaded firmware versions (see the
online release notes). Be aware that the network device firmware is not downwards
compatible and could cause a fault message. In the diagnose section, see
Version,
page 107
.
View the message(s) of the device(s) from which the firmware upload failed and
start the uploading process again.
If the upload still fails, do the following:
Power off/on the failed network device and start uploading again. And/or:
Restart the system controller.
10. If the error(s) still appears, contact your Bosch (service) representative. If required, see
Troubleshooting, page 133
.
2- Secure firmware upload
A secure firmware upload means that the data communication and connection between the
firmware upload tool / computer and the PRAESENSA system (controller) configuration is
secured against visibility and using of the firmware by unauthorized people and/or devices:
The secure firmware upload process is similar to the 1
st
time firmware upload, with the
exception of some extra firmware upload tool settings and configuration logon
credentials as described following.
To do so:
1. Execute the steps 1 up to 3 of the 1
st
time firmware upload.
2. Select and click > File > Options
A new screen Firmware Upload Tool Options appears
3. Enable (checkmark) checkbox Use secure connection.
4. Select a user name from the dropdown list or enter a new user name (click the > Manage
security user button and > click the Add button:
A new screen, Security user appears.
5. Enter the OMNEO User name, Passphrase and Confirm Passphrase in the appropriate
text box and click > OK:
IMPORTANT: Retrieve your OMNEO security username and passphrase from the
PRAESENSA configuration. See
Logon the application, page 35
and/or
System
security, page 113
.
IMPORTANT: Only after the 1
st
time / initial firmware upload and 1
st
time / initial
configuration logon a OMNEO security username and passphrase are available. Both
credentials are automatically generated during the configuration logon process.
Now the firmware upload process will use a secured data connection with the
PRAESENSA configuration.
6. Proceed with the steps 4 up to 8 (and when required the steps 9 and 10) of the 1- 1
st
time firmware upload procedure previously described in this section.