13-20 Appendix Rexroth IndraDrive
DOK-INDRV*-HMV-*******-PR01-EN-P
Versions
Filter Type Supply Unit/
Frequency Converter
Mains current
[A
eff
]
Limit Values
EN61800-3
1)
HFD01.2-480-0026 1 HMV01.1R-W0018 26 class A, group 2 (curve 2.1/2.2)
HFD01.2-480-0065 1 HMV01.1R-W0045; HMV01.1E-
W0030
65 class A, group 2 (curve 2.1/2.2)
HFD01.2-480-0098 1 HMV01.1R-W0065 94 class A, group 2 (curve 2.1/2.2)
HFD01.2-480-0125 1 HMV01.1E-W0075 125 class A, group 2 (curve 1.1/1.2)
HFD01.2-480-0202 1 HMV01.1E-W0120 202 class A, group 2 (curve 1.1/1.2)
HFD02.2-480-0026 2 HMV01.1R-W0018 26 class A, group 2 (curve 2.1/2.2)
HFD02.2-480-0065 2 HMV01.1R-W0045; HMV01.1E-
W0030
65 class A, group 2 (curve 2.1/2.2)
HFD02.2-480-0094 2 HMV01.1R-W0065 94 class A, group 2 (curve 2.1/2.2)
HFD02.2-480-0125 2 HMV01.1E-W0075 125 class A, group 2 (curve 1.1/1.2)
HFD02.2-480-0202 2 HMV01.1E-W0120 202 class A, group 2 (curve 1.1/1.2)
HFD03.2-480-0026 3 HMV01.1R-W0018 26 class B, group 1 (curve 4.1/4.2)
HFD03.2-480-0065 3 HMV01.1R-W0045; HMV01.1E-
W0030
65 class B, group 1 (curve 4.1/4.2)
HFD03.2-480-0094 3 HMV01.1R-W0065 94 class B, group 1 (curve 4.1/4.2)
1) see following figure
Fig. 13-22: Versions
Limit values for line-based disturbances (DIN EN 55011 / DIN EN 61800-3/A11)
1.1
1.2
2.1
3.1
4.1
2.2
3.2
4.2
1.1
1.2
2.1
2.2
3.1
3.2
4.1 4.2
130
120
100
90
79
66
56
125
115
86
76
60
56
46
115
105
73
50
60
70
class A, group 2 , QSP, I > 100A
(second environment)
class A, group 2 , AV, I < 100A
(
second environment
)
class A, group 1 , QSP,
(first environment, restricted
distribution, first environment also if
source of interference in second
environment
)
class A, group 1 , AV,
(first environment, restricted
distribution, first environment also if
source of interference in second
environment)
class B, group 1 , QSP,
(first environment, general
distribution, first environment also if
source of interference in second
environment)
class B, group 1 , AV,
(first environment, general
distribution, first environment also if
source of interference in second
environment)
class A, group 2 , AV, I > 100A
(second environment)
class A, group 2 , QSP, I < 100A
(second environment)
QSP: quasi peak value
AV: average value
Fig. 13-23: Limit values for line-based disturbances (DIN 55011/DIN 61800-
3/A11)