EasyManua.ls Logo

Bosch Rexroth IndraDrive HMV01.1R-W0045 - 7 Electrical Installation; General Information and EMC

Bosch Rexroth IndraDrive HMV01.1R-W0045
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rexroth IndraDrive Electrical Installation 7-1
DOK-INDRV*-HMV-*******-PR01-EN-P
7 Electrical Installation
7.1 General Information
Damage can be caused to the supply unit or circuit boards if electrostatic
charging present in people and/or tools is discharged across them.
Therefore, please note the following information:
CAUTION
Electrostatic charges can cause damage to
electronic components and interfere with their
operational safety!
Objects coming into contact with components and
circuit boards must be discharged by means of
grounding. Otherwise errors may occur when
triggering motors and moving elements.
Such objects include:
the copper bit when soldering
the human body (ground connection caused by touching a conductive,
grounded item)
parts and tools (placing on a conductive support)
Endangered components may only be stored or dispatched in conductive
packaging.
Note: Rexroth connection diagrams are only to be used for
producing installation connection diagrams. The machine
manufacturers installation connection diagrams must be used
for wiring the installation!
Lay signal lines separately from the load resistance lines because of
the occurrence of interference.
Feed analog signals (e.g., command values, actual values) via
sheathed lines.
Do not connect mains, DC bus or power leads to low voltages or allow
them to come into contact.
When carrying out a high voltage or insulation test withstand test on
the machines electrical equipment, disconnect all connections to the
units. This protects the electronic components (permitted in
accordance with EN 60204-1). During their routine check test, Rexroth
drive components are tested for high voltage and insulation in
accordance with EN 50178.
CAUTION
Plugging and unclamping live connections can
damage the controller.
Do not plug in or unclamp live connections.

Table of Contents

Related product manuals