7-22 Electrical Installation Rexroth IndraDrive
DOK-INDRV*-HMV-*******-PR01-EN-P
X2, RS232
RS232 Interface
The RS232 interface is required for diagnosis during commissioning and
servicing.
PS2_stecker_hmv.fh7
1
2
3
4
5
6
7
8
Fig. 7-17: X2
Type Number of poles Type of design
MiniDIN 8 socket on device
Fig. 7-18: Design
Cross section
single-wire
[mm²]
Cross section
multiwire
[mm²]
Cross section
in AWG
Gauge No.
-- 0.25 – 0.5 --
Fig. 7-19: Connection cross section
n.c.
1
n.c.
2
RS232_TxD
3
GND
4
RS232_RxD
5
n.c.
6
n.c.
7
n.c.
8
GND is connected to the housing.