7.6 Touch Guard
WARNING
Lethal electric shock caused by live parts with
more than 50 V!
The appropriate touch guard must be mounted for
each supply unit following connection work.
Never mount a damaged touch guard.
Immediately replace a damaged touch guard by an
undamaged touch guard.
Cutouts
hms_beruehrschutz_seite.fh7
A
B C
Fig. 7-40: Cutouts at the touch guard
WARNING
Lethal electric shock caused by live parts with
more than 50 V!
You have to provide the best possible protection
against contact. Therefore keep the cutouts at the
touch guard as small as possible.
Only break off the cutouts if necessary.
If the DC bus and the control voltage are connected by means of
contact rails, only the cutout C (see picture) may be broken off the
touch guard.
If the DC bus and the control voltage are connected by means of
cables (e.g. in the case of multiple-line arrangement of the drive
controllers), the cutouts A, B and C (see picture) may be broken off
the touch guard.