Rexroth IndraDrive Electrical Installation 7-31
DOK-INDRV*-HMV-*******-PR01-EN-P
7.6 Touch Guard
WARNING
Lethal electric shock caused by live parts with
more than 50 V!
⇒ The appropriate touch guard must be mounted for
each supply unit following connection work.
⇒ Never mount a damaged touch guard.
⇒ Immediately replace a damaged touch guard by an
undamaged touch guard.
Cutouts
hms_beruehrschutz_seite.fh7
A
B C
Fig. 7-40: Cutouts at the touch guard
WARNING
Lethal electric shock caused by live parts with
more than 50 V!
⇒ You have to provide the best possible protection
against contact. Therefore keep the cutouts at the
touch guard as small as possible.
⇒ Only break off the cutouts if necessary.
• If the DC bus and the control voltage are connected by means of
contact rails, only the cutout C (see picture) may be broken off the
touch guard.
• If the DC bus and the control voltage are connected by means of
cables (e.g. in the case of multiple-line arrangement of the drive
controllers), the cutouts A, B and C (see picture) may be broken off
the touch guard.