Rexroth IndraDrive Transport and Storage 5-1
DOK-INDRV*-HMV-*******-PR01-EN-P
5 Transport and Storage
5.1 Transporting the Devices
Conditions
temperature -25 ... 70 °C
relative humidity 5 ... 95%;
climatic category 2K3
absolute humidity 1 ... 60 g/m
3
climatic category 2K3
moisture condensation not allowed
icing not allowed
Shock check not in operation
according to EN 60068-2-27
Halve sine in 3 axis:
10g / 11ms
Fig. 5-1: Conditions for transport
5.2 Storing the Devices
Conditions
temperature -25 ... 55 °C
relative humidity 5 ... 95%;
climatic category 1K3
absolute humidity 1 ... 29 g/m
3
climatic category 1K3
moisture condensation not allowed
icing not allowed
Fig. 5-2: Conditions for storage
In Case of Long Storage Periods
The power supply units contain sensitive electrolytic capacitors.
Therefore, in the case of long storage periods, operate the power supply
units once a year for at least 1 hour with power on (DC bus voltage must
be applied).