36/68 Bosch Rexroth AG Training system mMS 4.0 | R901429162/04.16
Technical data and dimensions
6 Technical data and dimensions
6.1 Technical data
6.1.1 Training system mMS 4.0
Table 7: Technical data for mMS 4.0 training system
Designation
Unit
Value
Total weight
kg
300
Dimension
Max. length
mm
2400
Max. width
mm
740
Max. height
mm
1900
Min. operating temperature
°C
+ 20
Max. operating temperature
°C
+ 60
Place of installation
Closed room
Ambient temperature
°C
+ 5 to +55
Max. relative air humidity
%
90 at 20 °C
Max. installation height
m
1000 above sea level
Pneumatics
Max. operating pressure
bar
6
Min. operating pressure
bar
4
Supply
Connection- / operating
voltage
V
115-230 (AC)
Control voltage
V
24 (DC)
Frequency
Hz
50-60
Nominal power
kW
Fuse
A
16
Protective earthing
PE (ground or
FI circuit breaker)
A-weighted continuous sound level
(at workplace of operating personnel
during pumping)
dB (A)
< 70