220
Inspection and maintenance
Inspection Tests Maintenance
Accept-
ance
Rejection
Drive/gear shift
Chain/
cassette/
pinion/
chainring
6 months Check for damage Check for
damage
O.K. Damage Refasten if neces-
sary or replace as
specified in parts list
Chain guard/
spoke guard
6 months Check for damage Check for
damage
O.K. Damage Replace as speci-
fied in parts list
Bottom
bracket axle/
crank
6 months Check mount
fastening
Check mount
fastening
O.K. Loose Retighten screws
Pedals
6 months Check mount
fastening
Check mount
fastening
O.K. Loose Retighten screws
Shifter
6 months Check mount
fastening
Check mount
fastening
O.K. Loose Retighten screws
Shift cables
6 months Check for damage Check for
damage
O.K. Loose and
defective
Adjust shift cables;
new shift cables if
necessary
Front
derailleur
6 months Check for damage Check for
damage
O.K. Gear shift
difficult or not
possible
Adjust
Rear
derailleur
6 months Check for damage Check for
damage
O.K. Gear shift
difficult or not
possible
Adjust
Electric drive system
On-board
computer
6 months Check for damage Check for
damage
O.K. No screen,
defective
screen
display
Restart, test battery,
new software or
new on-board com-
puter, decommis-
sioning,
Control panel
6 months Check control panel
for damage
Check for
damage
O.K. No response Restart; contact
control panel manu-
facturer, new con-
trol panel
Tachometer
6 months Calibration Speed meas-
urement
O.K. Pedelec
travelling
10% too fast/
slow
Take pedelec out of
service until the
source of the error
is found
Cabling
6 months Visual inspection Visual inspec-
tion
O.K. Failure in
system,
damage,
kinked cables
New cabling
Recharge-
able battery
6 months First examination See
Section on
Assembly
O.K. Error
message
Contact battery
manufacturer; take
out of service, new
battery
Battery mount
6 months Firmly in position,
lock, contacts
Check mount
fastening
O.K. Loose; lock
doesn't close,
no contacts
New battery mount
Motor
6 months Visual inspection
and mount
Check mount
fastening
O.K. Damage,
loose
Refasten motor,
contact motor man-
ufacturer, new
motor; take out of
service
Software
6 months Check version Check soft-
ware version
In latest
version
Not latest
version
Import update
Components Frequency Description Criteria
Measures if
rejected

Table of Contents