AirborneM2M™ User Guide
61
CONFIGURING SERIAL PORT 1 AS TCP CLIENT
In this mode, the device will attempt to initiate a TCP connection to a network-based server and establish a
data tunnel with Serial Port 1 on a successful network connection.
Table 37 - Configure Serial Port 1 as TCP Client
Step Description
Navigation Bar
Select Configuration
You will see a group of fields under the banner of WLAN
Parameters.
Feature Link
Select Connection Settings
The wireless interface and security must be configured before
configuring the Ethernet settings.
A page showing the configuration options for TCP/IP and UDP
connections to the device. Configuration of Telnet, HTTP and SSH
ports is possible through this page.
Select TCP Port Enter the port on which the target server is listening for TCP
connections.
Select TCP Timeout Enter the inactivity timeout in seconds, after which the device will
close the open data tunnel on Serial Port 1.
The default 0 disables the timeout.
Select TCP Retry Time Enter the period (in seconds) the device should use to retry
establishing the TCP connection to the target server.
Select Primary TCP Target Server IP
Address
Enter the IP address of the primary target server.
The address must be in the format:
XXX.XXX.XXX.XXX
Optional
Select Secondary TCP Target Server
IP Address
Enter the IP address of the secondary target server.
The address must be in the format:
XXX.XXX.XXX.XXX
This address will be used if the initial attempts to connect to the
primary server fail. This field is optional.
Press Commit [Button] Saves changes to the device.
Press Reload [Button] Reloads the Connection Settings page.
Feature Link
Select Serial Port 1 Settings
The wireless interface and security must be configured before
configuring the Ethernet settings.
Displays a page showing the serial port configuration. Setting the
default mode of operation for the serial interface is done in this
page.
Select Serial CLI Default Mode Select Pass from the drop down menu.
Press Commit [Button] Saves changes to the device.
Optional
Press Reload [Button]
Reloads the Serial Port 1 Settings page. Select this if you have
further configuration options to change.
Optional
Press Restart [Button]
Restarts the device. After the device as rebooted, it will attempt to
authenticate to the configured network. As long as the network is in
range, the wireless interface will connect.
Once authenticated to the network, the device will attempt to make
a TCP connection with primary target server, using the configured
port number.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the B+B SmartWorx Airborne M2M ABDN-er-DP55 Series and is the answer not in the manual?

B+B SmartWorx Airborne M2M ABDN-er-DP55 Series Specifications

General IconGeneral
BrandB+B SmartWorx
ModelAirborne M2M ABDN-er-DP55 Series
CategoryNetwork Hardware
LanguageEnglish