BradyPrinter i3300 32
Maintenance
Cleaning the Printer
Cleaning the Sensors
The supply and cutter sensors are located inside the printer and may be covered with dust that results
from cutting the labels. One of the supply sensors is located under the yellow supply guide, as shown
in the picture below. The cutter sensor is located above the cutting blade and is visible only when the
cutter is released.
Materials Required
BradyPrinter i3300
Cleaning Kit (Cat # B31-CCT)
Isopropyl Alcohol
1. Remove power and supplies from the printer (see Pre-maintenance Operations” on page 27).
2. Squeeze the two yellow cutter tabs to release the cutter; the cutter mechanism and exit chute
will slide down exposing the cutter sensor.
3. With a pre-moistened foam swab, gently wipe the surface of the cutter sensor [11] and the two
supply sensors [10] at the locations shown:
a. Center die-cut sensor [10a]
b. Label out/die-cut sensor [10b]
Note: Sensor is located under the yellow supply guide
11
10a
10b