2. FUNCTION SETTINGS
20
BAS-342G
2-8. Output checking method
Use this to check for any malfunctions of the circuit boards, and for checking for problems with drive mechanisms and broken
cords.
You can check whether the signals being output by the CPU are driving the mechanisms correctly.
1. While pressing the
key (1), turn on the power switch.
* Keep pressing the
key (1) until the model name is
displayed and the buzzer beeps once.
The check code will be displayed in the PROGRAM No.
display (2), and the abbreviated name of the output will
be displayed in the menu display (3).
2. Press the
key (4) or key (1) to select the desired
check code.
3. The operations for check codes 51 to 54 can be checked
by pressing the
or key (5).
4. For check codes 55 and after, lower the work clamp and
then depress the start switch (6).
5. To return to normal operation, turn off the power switch
and then turn it back on again.
Program No.
display
Menu display
Check code Name
Operating details
[ 51] [PM-X]
When the
key is pressed, the work clamp moves to the left.
When the
key is pressed, the work clamp moves to the right.
[ 52] [PM-y]
When the
key is pressed, the work clamp moves forward.
When the
key is pressed, the work clamp moves back.
[ 53] [PM-F]
When the
key is pressed, the work clamp is raised.
When the
key is pressed, the work clamp is lowered.
[ 54] [CAtH] No devices are compatible with the BAS-342G.
[ 55] [CL-r] The right clamp valve (clamp valve 1) is turned ON (OUT16) (*1)
[ 56] [CL-L] The left clamp valve (clamp valve 2) is turned ON (OUT15) (*1)
[ 57] [SUPt] Auxiliary tension release valve is turned ON (OUT14) (*1)
[ 58] [FLiP] Inner clamping device valve is turned ON (OUT13) (*1)
[ 59] [CooL] Needle cooling valve is turned ON (OUT12) (*1)
[ 60]
The panel LEDs illuminate in order, and then the seven segments of the
PROGRAM No. display and the menu display illuminate one by one.
*1 Applies when corresponding devices are installed.
The corresponding operation for the check code will
be carried out while the start switch is being
depressed (while the start switch has been
depressed once for check code 60).