5-23
Regular Maintenance
(5) Head is temporally uncapped during the exhaust cleaning operation. Confirm presence of the ink within the cap
during this time.
<IMPORTANT>
ï‚· In case cap is not filled with ink, there is a possibility that the exhaust opening is clogged. In this situation, clean exhaust
opening.
(6) After cleaning exhaust opening, select [Output Check] from the Advanced menu and select the [Carriage Test] >
[To Center].
(7) Confirm discharge of ink into the cap.
<IMPORTANT>
ï‚· In case ink within the cap is not discharged, there is a possibility that the exhaust opening is clogged. In this situation, clean
exhaust opening.