T104 Series Indicators EN-43
8.3 Output Format
The default serial output format is shown below.
Field: Polarity Weight Space Unit Stability Legend CR CF
Length: 1 7 1 5 1 3 1 1
Definitions: Polarity, “-” sign if negative, blank if positive.
Weight, up to 6 numbers and 1 decimal, right justified, leading zero blanking.
Units, fixed 5 characters, left justified.
Stability, “?” character is printed if not stable, blank if stable.
Legend, up to 3 characters: G = gross weight, NET = net weight, T = tare
The continuous output format is shown below.
Field: STX Polarity Weight Unit G/N Stability CR LF
Length: 1 1 7 1 1 1 1 1
Definitions: STX
,
ASCII <002> start of text
Polarity, “-” sign if negative, blank if positive.
Weight, 7 digits, right justified, leading zeros transmit as spaces, one leading zero will precede the
decimal point.
Units, L=lb; K=kg; T=t; O=oz; G=g, blank=GN, Troy oz, Troy Ib, or none
G/N, G = gross weight, N = net weight
Stability, blank if stable, M= Motion, O= Over / Under Load Range