Logamatic EMS RC35 user interface - Subject to technical modifications. 19
Commissioning
5
5.2 Checklist: important parameters for commissioning
When putting the device into service, ensure that the heating system settings meets the customer's
needs and expectations. In our experience, the following parameters are very important for the
satisfaction of the system owner.
B Find out the system owner's requirements and preferences regarding ...
Input range Factory setting
Service menu\
Settings\
... the desired setback
mode (night setback)
Outdoor setback mode
Room setback mode
setback mode
shutdown operation
Outdoor setback
mode
heating zone x,
page 29
... the desired control
mode
outdoor reset control
room reset control
outdoor reset
control
heating zone x,
page 32
... the correct heating
characteristics
By means of the
following parameters:
standard temperature,
minimum outdoor
temperature, offset, and
target room temperature
heating zone x,
page 28
... the correct type of
building (“delayed”
response to outdoor
temperature)
light
medium
heavy
medium system data,
page 25
... the switch-on
frequency of the
DHW circulation pump
Permanent, 1 x, 2 x, 3 x,
4 x, 5 x, 6 x per hour for
3 min each time
2 x domestic hot
water,
page 38
... DHW Priority yes
no
yes heating zone x,
page 30
... program
(times)
Standard program
e.g. family,
custom program
family heating zone x,
page 31
Tab. 7 Checklist: important parameters for commissioning