PMW20
72
PMW20
73
8.1 ELECTRICAL MAINTENANCE DIAGNOSIS
1) The alarm code of the display is shown as "Exx" while the alarm error code of the
controller is displayed as “number”.
2) If there is no fault, it is green background. Instead, it is red background.
8.2 COMPARISON TABLE OF THE DISPLAY ERROR CODES AND
CONTROLLER ERROR CODES
ID
PARAMETER
(CONTROLLER)
DATA DOMAIN 3
FAULT CODES
(DISPLAY)
DEFINITION
0x288 66 02A66
BATTERY LOW
0x288 247 02A00
DATA ACQUISITION
0x288 249 02A00
CHECK UP NEEDED
0x288 8 02A08
WATCHDOG
0x288 221 02A09
FLASH CHECKSUM
0x288 231 02A08
WATCHDOG#2
0x288 212 02A10
WRONG RAM
0x288 209 02A11
STALL ROTOR
0x288 17 02A17
LOGIC FAILURE #3
0x288 244 02A27
PHASE KO
0x288 28 02A28
PUMP VMN LOW
0x288 29 02A29
PUMP VMN HIGH
0x288 31 02A31
VMN HIGH
0x288 203 02A32
PUMP VMN NOT OK
0x288 254 02A40
AUX DRIV.SHRT
0x288 251 02A41
WRONG BATTERY
0x288 246 02A42
AUX DRIV.OPEN
0x288 241 02A49
LIFT + LOWER
0x288 228 02A51
TILLER OPEN
0x288 52 02A52
PUMP I=0 EVER
0x288 53 02A53
STBY I HIGH
0x288 252 02A58
WRONG ZERO
0x288 19 02A54
LOGIC FAILURE #1
0x288 18 02A55
LOGIC FAILURE #2
0x288 217 02A56
PUMP I NO ZERO
SM-PMW202020001-EN
SM-PMW202020001-EN