EasyManua.ls Logo

BYD PMW20 - Parameters of the Controller

BYD PMW20
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PMW20
196
10.5 PARAMETERS OF THE CONTROLLER
Description
Name
Current
Value
Menu
ACCELER. DELAY 1.5
Time (Unit:S) required when
the accelerator is released and
the motor accelerates from 0H
to 100Hz
RELEASE BRAKING
0.8
TILLER BRAKING
0.4
3.5
Deceleration rate of
upright braking
INVERS. BRAKING 0.5
DECEL. BRAKING 2.5
PEDAL BRAKING 1
SPEED LIMIT BRK. 2.8
Speed reduction rate
EPS STEER BRAK. 0.5
MAX SPEED FORW 90%
Percent showing max. speed
forward
MAX SPEED BACK 90%
Percent showing
max. speed backward
HYD SPEED FINE 16%
Unused
HYDRO COMPENS. 10%
Unused
PMW20
197
CUTBACK SPEED 50%
Unused
H&S CUTBACK 35%
Unused
THMOT AL. CUTB. 50%
Temperature sensor alarm
for speed limit 50%
BDI AL. CUTBACK
50%
STEER CTB.1 80%
STEER CTB.2 60%
STEER CTB.3 40%
STEER CTB ANGL 1 20 ?0
STEER CTB ANGL 2 40 ?0
STEER CTB ANGL 3 80 ?0
TURTLE H&S TIME 1
RETURN TIME 10
TURTLE TIME DISP 1
F REQUENC Y
CREEP
0.60 Hz
100%
ACC SMOOTH 1
Parameter Change
SM-PMW202020001-EN
SM-PMW202020001-EN
Description
Name
Value
Menu
Current
Time (Unit:S) required when
the motor accelerates from 0H
to 100Hz
Time (Unit:S) required when
the tiller switch is closed and
the motor decelerates from
100H to 0Hz
UPRIGHT BRAKING
Time (Unit:S) required when
the switch reverses rapidly and
the motor decelerates from
100H to 0Hz
Time (Unit:S) required when
the accelerator is partly
released and the motor
accelerates from 0H to 100Hz
Time (Unit:S) required when
the brake switch is closed and
the motor decelerates from
100H to 0Hz (except for the
pallet truck)
(Except for the mechanical
steering pallet truck)
Parame ter Change
Battery level is 10% and
the speed limit is 50%.
Unused state. Relevant with
electric steering. Speed limit at
curves.
Parame ter Change
Unused state. Relevant with
electric steering. Speed limit at
curves.
Unused state. Relevant with
electric steering. Speed limit at
curves.
Unused state. Creep frequency
can only appear through the
direction switch.
Parame ter Change
Parame ter Change
Parame ter Change
Parame ter Change
Parame ter Change
Parame ter Change
Parame ter Change
Parame ter Change
Parame ter Change
Parame ter Change
Parame te r Change
Parame ter Change
Parame ter Change
Parame ter Change
Parame ter Change
Parame ter Change
Unused state. Relevant with
electric steering. The angle of
the handle is 20 degrees.
Speed is declined to 80%.
Speed limit at curves.
Unused state. Relevant with
electric steering. The angle of
the handle is 40 degrees.
Speed is declined to 60%.
Speed limit at curves.
Unused state. Relevant with
electric steering. The angle of
the handle is 80 degrees.
Speed is declined to 40%.
Speed limit at curves.
Enter handle upright mode
(Long press the turtle speed).
Return time of the handle
upright mode
Flashing frequency of the turtle
icon
The maximum current output of
the controller (in walking
mode). Not adjusted.
Acceleration smoothness
(rarely used). The minimum
value is 1S.
Parame ter Change
Parame ter Change
Parame te r Change
Parame ter Change
Parame ter Change
Parame ter Change
Parame ter Change
MAX IMUM
CURRENT
Parame ter Change
Parame ter Change
Parame te r Change

Table of Contents