PMW20
198
PMW20
199
INV SMOOTH 1
STOP SMOOTH 20 Hz
BRK SMOOTH 1
20 Hz
AUXILIARY TIME 0.5
HYDRO TIME 5
The pump motor stops in delay.
PUMP IMAX LEVEL = 9
Maximum output current of the
Pump motor is controlled.
PU. ACCELER. DEL 0.5
Pump acceleration is delayed.
PU. DECELER. DEL 0.5
Pump deceleration is delayed.
MAX SPEED LIFT 100%
Maximum lifting speed
10%
Minimum speed when the
pump starts.
10%
Pump speed compensation
MIN EVP 6.3
MAX EVP 97.6
EVP OPEN DELAY 0.3
The lowering solenoid valve
opens in delay.
EVP CLOSE DELAY 0.3
The lowering solenoid valve
closes in delay.
SPEED RED 1 55%
Unused
SPEED RED 2 30%
Unused
ACC DELAY BELLY 0.3
Time when the motor declines
to 0 in quick reverse.
DEC DELAY BELLY 0.3
TILLER DELAY 0.1
Tiller is delayed.
TILLER SWITCH HANDLE Set Options
EB ON TILLER BRK OFF Set Options
HOUR COUNTER RUNNING Set Options
Hour counter. It is running
time.
EVP TYPE DIGITAL Set Options
BATTERY CHECK LEVEL = 1 Set Options
Unused
20% Set Options
An alarm for battery level 20%.
The lifting function is not
limited.
10%
Set Options
An alarm for battery level 10%.
The lifting function is limited and
the driving speed is reduced to
50%.
STOP ON RAMP ON Set Options Stop on ramp
QUICK INVERSION TIMED Set Options Quick inversion function
OPTION #1 Set Options
Set the type of the motor
temperature sensor.
EPS NONE Set Options
Show whether there is electric
steering.
MC HSD ON EPS ABSENT Set Options Unused
DEBUG ON CAN ON Set Options Unused
EV1 DIGITAL Set Options Unused
EV2 DIGITAL Set Options Unused
EV3 DIGITAL Set Options Lift solenoid valve
HORN DIGITAL Set Options Horn relay
SM-PMW202020001-EN
SM-PMW202020001-EN
Description
Name
Current
Value
Menu
Description
Name
Current
Value
Menu
Parameter Change
Parame te r Change
Parame te r Change
Deceleration smoothness in
reverse (rarely used). The
minimum value is 1S.
Parking smoothness (rarely
used). It can only be adjusted
downward.
Brake smoothness (rarely used).
The minimum value is 1S.
Parking brake smoothness
(rarely used). It can only be
adjusted downward.
Unused state. The auxiliary
time is used in conjunction with
STOP ON RAMP.
STOP BRK SMOOTH
PUMP CREEP
SPEED
PUMP
COMPENSAT.
The minimum output value
of the lowering solenoid valve
The maximum output value
of the lowering solenoid valve
Parameter Change
Parame ter Change
Parame ter Change
Parameter Change
Parame ter Change
Parame ter Change
Parameter Change
Parame ter Change
Parame ter Change
Parame ter Change
Parameter Change
Parame ter Change
Parame ter Change
Parameter Change
Parame te
r Change
Parame ter Change
The motor declines to 0 in
quick reverse and then
accelerate to the preset speed
in reverse.
Interlock type. Handle switch.
Seat-typed.
Show whether the
electromagnetic brake is locked
when the handle is in
emergency braking
The lowering solenoid
valve is switching mode
(on/off) or analog quantity.
Default option.
B AT T.LOW LED
TSH
BAT T .LOW
TRESHLD
SETMOT.
TEMPERAT

Table of Contents

Related product manuals