TOTAL LITE Revision 1
SERVICE MANUAL FOR INNOVATION TOTAL LITE Single-Cup Brewer
61
9.4 Hot Water Tank
PM: every 60,000 cycles, quarterly inspection
To avoid any problems related with mineral
deposits over time, we recommend having the
water tank assembly delimed to remove all scale
in the unit. Upon visual inspection, you may wish
to replace the element, probe and the water
level and heater safety switch.
Use a scale remover product such as Scale
Kleen by Everpure.
See the manufacturer instructions for more
details.
Preventive Maintenance
Heater switch
Water level switch
Element
Probe