11.2 Error message list (continued)
Low water level in tank.
The water tank tank failed to ll to maximum within the required time. The water inlet valve is de-
activated as a safety.
Maximum lling time is 4 minutes when you power ON the coffee brewer.
Maximum lling time is 1 minute after the rst tank ll.
Check water supply line for proper pressure. If you are using a waterline lter, it might be worn out and
needs to be replaced.
Press button on screen to restart the tank lling process.
Water tank not full. Please wait while lling. 1 to 3 minutes.
This message will be on screen after powering ON the coffee brewer until water tank gets full.
Water temperature not high enough.
The TOTAL LITE will stop dispensing drinks if actual water temperature is below the ‘Warming up’
temperature in the service menu, ‘system’ tab. To disable this feature set the warming up temperature
to 0.
Troubleshooting