ERROR MESSAGE
The error messages appear on the display.
E 2 Door-travel calibration incomplete
E 3 Encoder broken
E 4 Services test error
E 7 Operating time error
E 9 Closing obstruction
E11 Maximum number of obstructions consecutively detected
E14 Serial communication error
E15 Transmitter error
E17 Wireless system error
E18 The wireless system confi guration is missing
Obstruction detection when CLOSING.
The door inverts its travel direction and reopens.
After two consecutive inversions, when closing, the door stays open and the automatic closing is excluded. After
three consecutive detections, when opening and/or closing, the door stops.
To reclose the door, press a control button or use the transmitter.
Encoder operation
Obstruction detection when OPENING.
The door recloses.
Page 31 - Manual FA01358-EN - 07/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAME VER-PLUS Series and is the answer not in the manual?

CAME VER-PLUS Series Specifications

General IconGeneral
BrandCAME
ModelVER-PLUS Series
CategoryGarage Door Opener
LanguageEnglish

Related product manuals