3
WARRANTY ....................................................................4
Certifications and Approvals ..........................................4
System Overview...........................................................4
COMPONENTS ...............................................................5
Cylinder Tank Assembly ................................................6
Cylinder Tank and Actuator Bracket ..............................7
Discharge Adapter .........................................................7
Nozzles ..........................................................................8
Primary Actuator Kit (PAK) ............................................8
Secondary Valve Actuator (SVA) and Hose ..................9
Supervisory Pressure Switch.........................................9
Gas Shut-Off Valves ....................................................10
Electric Remote Manual Release ................................10
Firestat (Heat) Detector ...............................................10
INSTALLATION .............................................................11
Cylinder Tanks.............................................................11
Removing Full Cylinder Tanks (Optional) ....................12
Primary and Secondary Actuator Installation...............12
Primary Actuator Kit (PAK) ......................................13
Secondary Valve Actuator (SVA) .............................13
Supervisory Pressure Switch.......................................14
Duct and Plenum Protection ........................................15
Plenum Protection ....................................................15
Duct Protection ........................................................16
Ventilation Exhaust and Dampers ...............................18
Electrostatic Precipitators (ESP)..................................18
Appliance Protection....................................................19
Overlapping Appliance Protection ............................19
Appliance Coverage ....................................................20
Coverage Exceptions ...............................................21
Overlapping Protection ............................................22
Overlapping Coverage - Group Protection ...............22
Upright Broiler/Salamander Protection ....................24
Appliance with Shelf .................................................25
Wok Protection .........................................................26
Large Wok Protection ..............................................27
Appliance with Upright Obstruction ..........................28
Appliance with Overhead Salamander .....................29
Pizza Ovens .............................................................30
Agent Distribution Piping .............................................32
Cylinder Nozzle and Piping Parameters ..................34
Nozzle Installation ....................................................34
Gas Shut-Off Valves ....................................................35
Hood Riser Sensor Replacement ................................37
Fire Protection Manual Actuation Device.....................38
Trouble Input Wiring ....................................................38
Fire Protection System Printed Circuit Board ..............39
Electrical ......................................................................42
Wire Ampacity Rating ..............................................43
Distance Limitations .................................................43
Fire Alarm Contacts .................................................43
Fire Group ................................................................44
Fire Protection System Supervised Loops...................45
Supervised Loop Electrical Details ..........................46
PCU Fire System .........................................................47
PCU Fire System Nozzles .......................................48
OPERATION .................................................................49
Test Mode Overview....................................................50
Reset Overview ...........................................................50
Battery Backup ............................................................51
Power Supply Adjustment............................................51
Fire Protection System Firestat ...................................52
Non-Solid Fuel Appliances (Rated 450°F) ...............52
Non-Solid Fuel Appliances (Rated 600°F) ...............52
Solid Fuel Appliances (Rated 700°F) .......................52
TROUBLESHOOTING ..................................................53
CORE Board Faults.....................................................54
Appliance Shutdown in Fault Conditions .....................55
Local Alarm Muting ..................................................55
Test Mode ................................................................55
Supervised Loop Wiring Troubleshooting....................56
DIP Switch Settings .................................................57
Typical DIP Switch Arrangement .............................58
START-UP/INSPECTION TEST PROCEDURE ...........59
Fire System Wiring Connections .................................59
Preparing System for Test...........................................59
Connecting Service Test Kit ........................................60
Balloon Test Procedure ...............................................62
Firestat Test Procedure ...............................................63
Disconnecting Service Cylinder Tank..........................63
Re-arming System.......................................................63
Leakage Testing ..........................................................64
Every Month (System Owner)......................................65
Every Six Months (Factory Trained Distributor)...........66
Every Two Years .........................................................66
Every Twelve Years.....................................................66
Decommissioning ........................................................66
Agent Cylinder Tanks ..............................................66
Actuation Hoses .......................................................66
Conditional Maintenance .............................................67
Replacing A Primary Actuation Kit ...........................67
Replacing A Secondary Valve Actuator ...................67
Adding Nitrogen to Tank(s) ......................................68
POST-DISCHARGE MAINTENANCE ...........................69
General Information .....................................................69
Appliance Cleanup.......................................................69
Cleaning Distribution System.......................................69
Cleaning Nozzles.........................................................69
Flushing the Distribution Pipe Network........................70
Flushing Procedure with Spare/Test Cylinder .............70
Flushing Procedure with an External Water Supply ....71
Flush the System .....................................................71
Dry the Lines ............................................................72
Cylinder Tank Maintenance .........................................73
Removing a Cylinder Tank (Empty or Storage) .......73
Install New Cylinder Tank(s) ....................................74
Depressurizing a Cylinder Tank ...............................75
Rechecking the System ...........................................75
Mobile Kitchen/Seasonal Shutdown ........................76
TANK FIRE SUPPRESSION SYSTEM PARTS ............77
Start-Up and Maintenance Documentation..................80
Job Information............................................................80