8200-M585-O1 Rev D 210 Installation & Technical 55
SETUP AND CALIBRATION, CONT.
SB-200 – (Type = 2)
If SB-200 is selected, the data will be transmitted in the following format:
<cr><s><xxxxxx><d><c><uu><m> ETX
Where:
cr = Carriage Return (hex 0D)
s = Sign "-" = negative, " " (blank) = positive
xxxxxx.xxx = Weight (with leading zeros)
d = Decimal point
Embedded into weight (after weight dpp=0)
c = status m = motion
o = overcap
e = weight not currently being displayed
uu = Units tn, lb, l/o, oz, t, kg, g
m = Mode G = Gross, N = Net
ETX = End of TeXt (hex 03) MUST terminate ALL serial commands
Rice Lake IQ355 – (Type = 3)
If Rice Lake IQ355 is selected, the data will be transmitted in the following format:
<stx><s>xxxxxxx<u><m><s><cr><lf>
AnDFV – (Type = 4)
If AnDFV is selected, the data will be transmitted in the following format:
<hdr1>,xxxxx<uu><cr><lf>
WI110 – (Type = 5)
If WI110 is selected, the data will be transmitted in the following format:
<m><sp><s>xxxxx<sp><uu><cr><lf>
Number Only – (Type = 6)
If number only is selected, the data will be transmitted in the following format:
xxxxxx<cr><lf>
Toledo Short – (Type = 7)
If Toledo Short is selected, the data will be transmitted in the following format:
<stx><swa><swb><swc>xxxxxx<cr><sum>
Where:
stx = Start of TeXt (hex 02)
swa =, swb=, swc= Status Bytes
xxxxxx= Displayed Weight, Gross or Net Weight (Six Digits)
cr = Carriage Return (hex 0D)
sum= Checksum Character