8200-M585-O1 Rev D 210 Installation & Technical 79
ID STORAGE OPERATION
The ID Storage feature has been designed to control three different types of transactions and
weighing operations. The first type of transaction assigns a permanent ID string, has a stored
tare weight, and accumulates net weight totals for the ID. The second type assigns a
permanent ID string and accumulates net weight totals for the ID, but does not have a
permanent stored weight. The third type temporarily assigns an ID string (while weighing in)
and does not accumulate any net weight totals for the ID.
PERMANENT
Single Pass Transaction (One-Step Operation)
The first type of permanent transaction is a "single pass" transaction and is used to weigh
loaded containers with a permanent ID string and a previously stored tare weight. The
stored tare weight requires weighing the empty container in advance or if the weight of the
empty container is known, by entering that value as a manual tare weight. The single pass
transaction completes a ticket and accumulates the net weight for the ID associated with the
container with a "one-step" weighing operation.
Two Pass Transaction (Two Step Operation)
The second type of permanent transaction is a "two pass" transaction and is used to weigh
the loaded container once when it is empty and once when it is loaded. A permanent ID
string and a previously stored zero (0) tare weight is required. In the two pass transaction,
the zero tare weight is replace by the new tare weight after the first pass and returned to
zero after the second pass when the transaction has been completed. The two pass
transaction requires a "two-step" weighing operation. On the first step, the incoming weight
will be stored and an interim ticket will be printed. On the second step, during the outgoing
transaction, a complete ticket will be printed and the net weight for the ID associated with
the container will be added to the accumulator.
TEMPORARY
Two Pass Transaction (Two Step Operation)
The third type is a temporary "two pass" transaction that also requires a "two-step"
operation. However, the ID string is only in memory while the container is weighed in and
out and the net weight will not be accumulated. In this type of transaction, on the first pass,
the container will be placed on the scale and an ID will be selected either by the operator
entering an ID string or by the indicator automatically assigning the ID string. The weight will
be stored and an interim ticket will be printed. On the second pass, the ID string is entered
and the stored weight is recalled for printing the complete ticket. After the ticket has printed,
the ID number and the stored weight will be removed from memory.
Gross Weight Alarm
If ALAr?=YES was selected setup, then when the PRESET key is pressed the ALr t prompt
is displayed. Press the ENTER key, the current weight value is displayed, if this value is
acceptable press the ENTER key, otherwise, use the numeric keys to enter a new alarm
weight and press the ENTER key.
NOTE: The gross weight must fall below 1/2 the preset weight before the alarm is re-
armed.
The ALr ti prompt is displayed, press the ENTER key and the alarm time on value in
seconds will be displayed. If the value is acceptable, press the ENTER key, otherwise, use the
numeric key to enter a new alarm time value and press the ENTER key. The alarm time may
be from 0 to 99 seconds.
NOTE: If the alarm time setting is zero, then the alarm is disabled.