8200-M585-O1 Rev D 210 Installation & Technical 32
SETUP AND CALIBRATION, CONT.
If you press the ENTER key at the SetUP prompt, you may proceed through to the next
section (up to and including f SPAn) by pressing the ENTER key.
If you press the ZERO key, dFLtS? is displayed. This allows all setup parameter values to be
replaced with predetermined defaults.
IMPORTANT! Setup may be interrupted at any time. ALL data previously
entered and finalized with the ENTER key will be retained in the non-volatile
memory.
Pressing the calibration switch at any prompt will return you to the SEtUP menu. To exit
setup, press the key with any of the above menu selections displayed or cycle power at any
time (press the ON/OFF key twice).
SEtUP
USA= (Domestic or International)
With SEtUP displayed, press the ENTER key. The display will change to USA=. Press the
ENTER key to show the current value. If the setting displayed is acceptable, press the ENTER
key again to save it. Otherwise, using the numeric keys, 0/NO or 1/YES, enter the new setting,
then press the ENTER key to save it.
USA=1 (Domestic) USA=0 (International)
Date = mm/dd/yy Date = dd/mm/yy
Trl = no Trl = yes
Cap + 4% to OC Cap + 9 grads to OC
PT printed with tare
Lamp test on power up
If you selected USA= 0 (International), an additional prompt, PASS= will be displayed.
If you selected USA= 1 (Domestic) proceed to LFt= (Legal For Trade).
PASS (Password Y/N)
The PASS (Password Y/N) prompt determines whether a password is required to enter Setup
and Calibration on indicators programmed for international use. Note that this prompt is only
displayed when USA = 0 (International) is selected.
With the display showing PASS, press the ENTER key to show the current value. If the setting
displayed is acceptable, press the ENTER key again to save it. Otherwise, using the numeric
keys, 0/NO or 1/YES, enter the new setting, then press the ENTER key to save it.
PASS (No) PASS (Yes)
Password protection is not needed.
Setup advances to the LFt= prompt
Password protection is desired. The
next prompt will be PASS=
NOTE: With the exception of the SEtUP prompt, the prompts displayed for each section
are different if you push the calibration switch instead of pressing the ENTER key to
proceed through the section. For example, if you press the calibration switch with the
SEtUP displayed, the next prompt displayed will be A-d. If you step through the setup
prompts by pressing the ENTER key, the next prompt displayed will be A-d?. In addition,
at a prompt with the ? displayed, you must press the ENTER key, the 1/YES key then the
ENTER key again to proceed with that section. To skip the section and advance to the next
menu selection, press the ENTER key twice.