8200-M585-O1 Rev D 210 Installation & Technical 33
SETUP AND CALIBRATION, CONT.
Press the ENTER key to see the current password value. If the password displayed is
acceptable, press the ENTER key again to save it. Otherwise, using the numeric keys enter
the new password (up to 6 digits) and then press the ENTER key to save it.
LFt= (Legal For Trade)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys, 0/NO or 1/YES, enter the
new setting, then press the ENTER key to save it.
LFt=1 LFt=0
Interval Settings (Int=) allowed
are: 1, 2, 5, 10 , 20, 50
Interval Setting (Int=) is
selectable from 1 to 99.
NOTE: When both
LFt=1
and
USA=1
, the followings results occur:
Scale must have between 100 and 10,000 divisions
Tra = .5 or 0 to 3
Inhibit serial data during input
Disables counting function in Normal Scale mode of operation (oPEr=0)
Date = mm/dd/yy
Trl = no
Cap + 4% to OC
Display will show Accnud momentarily whenever the Gross or Net
accumulator is updated
NOTE: When
LFt=1
and
USA=0
, the followings results occur:
Uns = 1
Date = dd/mm/yy
Trl = yes
Cap + 9 grads to OC
PT printed with tare
Lamp test on power up
Display will show Accnud momentarily whenever the Gross or Net
accumulator is updated
Unit1= (Weighing Unit 1)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are:
0 = none 4 = oz (ounces)
1= tn (tons) 5 = kg (kilograms)
2= g (grams) 6 = tonnes (metric tons)
3 = lb (pounds) 7 = lb/oz (pounds/ounces)
Password Operation
With the PASS prompt enabled (set to YES), anytime the operator tries to enter Setup, the
display will show the PASS= prompt requiring the operator to enter the correct password. If
the wrong password is entered the indicator displays ERROR momentarily and returns to the
weight mode. Note that the password is not displayed when the operator is entering it.
It is recommended to write the password down and store it in a secure
location. If the
password is forgotten or lost and a change to the indicator setup is required, the indicator
must be reprogrammed. WARNING! Reprogramming the indicator will erase all
the
contents of the Nov-Ram and memory.

Other manuals for Cardinal 210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cardinal 210 and is the answer not in the manual?

Cardinal 210 Specifications

General IconGeneral
BrandCardinal
Model210
CategoryAccessories
LanguageEnglish

Related product manuals