8200-M585-O1 Rev D 210 Installation & Technical 61
SETUP AND CALIBRATION, CONT.
tyPE3= (Continuous 3 Output Format)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are:
0 = SMA 1 = SB-400 2 = SB-200
3 = Rice Lake IQ355 4 = AnDFV 5 = WI110
6 = Number Only 7 = Toledo Long/Short 8 = SB500 with Traffic Light
9 = Ranger 5000 Format A
If tYPE3=7 (Toledo Long/Short) is selected, an additional prompt, tShort will
be displayed.
tShort= (Toledo Short)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys, 0/NO or 1/YES, enter the
new setting, then press the ENTER key to save it.
tShort= YES tShort= no
Toledo Short Output Format Toledo Long Output Format
thrs= (Threshold Weight)
If any of the Serial Ports have been configured for continuous SB-500 with Traffic Light output,
this prompt will be displayed.
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, use the numeric keys to enter a new value for the
threshold weight or enter a zero (0) to disable the traffic light and then press the ENTER key to
save it.
The threshold weight is used to automatically toggle between the RED and GREEN lights.
When the scale gross weight is less than the threshold weight, the GREEN light will be on,
otherwise the RED light will turn on and stay on until the weight goes below the threshold
weight or a ticket is printed.
When a ticket is printed, the GREEN light will turn on and stay on until the scale gross
weight goes below and back above the threshold weight and then the RED light will turn on.
NOTE: If you enter a zero (0) for the threshold weight (THRS=0), the traffic light feature
will be disabled (turned off).