8200-M585-O1 Rev D 210 Installation & Technical 90
DIGITAL FILL CONTROL MODE OPERATION, CONT.
To Suspend (Pause) or Stop (Abort) a Fill Operation in Progress
The fill operation can be suspended (paused) or stopped (aborted) by the operator if needed.
1. To pause the filling operation, press the Fn key or press the optional START pushbutton.
2. The fill operation will be suspended (paused) and the PAUSEd message will flash on the
display.
3. To continue the fill operation, press the Fn key. If the optional START pushbutton is
pressed go to step 7.
4. The Cont ? prompt will be displayed, press the ENTER key, the no prompt will be
displayed.
5. To stop (abort) the fill operation, press the ENTER key.
6. To continue the fill, press the 1/YES key or the optional START pushbutton.
7. The 210 will return to normal operation, displaying the Gross weight on the scale.
NOTE: If dGAtE=YES, the fill operation cannot be restarted after a STOP if the material
weight is above the zero tolerance.
NOTE: If the optional STOP pushbutton is pressed, the fill operation will immediately be
aborted.