8200-M698-O1 Rev B ļ 225 Installation and Technical
120
CONTINUOUS OUTPUT FORMATS, CONT.
SB-200 ā (Type= 10)
<cr><s><xxxxxx><d><c><uu><m><etx>
Where:
cr = Carriage Return (hex 0D)
s = Sign "-" = negative, " " (blank) = positive
Xxxxxx = Weight Six digits
d = Decimal point Always in data string
c = Weight Status O = over capacity
M = motion
e = weight not currently being displayed
uu = Units tn, lb, oz, t, kg, g
m = Mode G = Gross, N = Net
etx= End Text (hex 03)