8200-M698-O1 Rev B 225 Installation and Technical
58
CALIBRATION AND SETUP, CONT.
7. SCALE=X (SCALE USED FOR COM1 DATA)
With the COM1 SETUP MENU displayed the current setting for the SCALE= parameter
will be shown. Note that X is the current value. If the setting displayed is acceptable,
proceed to the next setup parameter.
Otherwise, press the 7 key, the ENTER key and then using the numeric keys, enter the
value for the scale the COM0 will receive data from and then press the ENTER key to
save the new setting and return to the COM1 SETUP MENU. Allowable values are 1
through 4. NOTE: Scale 1 is the default setting. Also, note, 0 is the current selected
scale and 4 is the TOTAL weight in multi-scale applications with totalizer.
NOTE: If you selected 5. SB500 for the TYPE= parameter, the following setup
parameters Manual Mode= and Thres Wt=will be shown on the COM 1
SETUP MENU.
9. Manual Mode=XX (MANUAL LIGHT MODE)
With the COM 1 SETUP MENU displayed the current setting for the
Manual Mode= parameter will be shown. Note that XXX is the current value. If the
setting displayed is acceptable, press EXIT (Navigation Keys UP Arrow) to return to
the Serial Menu.
Otherwise, press the 9 key, the ENTER key, YES or NO (on the soft keys) and then the
ENTER key to save the new setting and return to the COM 1 SETUP MENU.
Manual Mode=YES Manual Mode=NO
Manual Mode is Enabled. Pressing
START/STOP key will toggle traffic
light between Green and Red.
Manual Mode is Disabled.
Threshold weight is used to toggle
light between Green and Red.