8200-M698-O1 Rev B 225 Installation and Technical
57
CALIBRATION AND SETUP, CONT.
6. TYPE=X XXXXXXXXXX (COM1 CONTINUOUS OUTPUT SELECTION)
With the COM1 SETUP MENU displayed the current setting for the TYPE= parameter
will be shown. Note that X is the current value and XXXXXXXXXX is the description. If
the setting displayed is acceptable, proceed to the next setup parameter.
Otherwise, press the 6 key, the ENTER key and then using the numeric keys, enter the
value for the COM0 continuous output selection and then press the ENTER key to save
the new setting and return to the COM1 SETUP MENU. Allowable values are 0 through
7 and 9.
0 = SMA 4 = NUMERIC WT 9 = TALLEY (See Note 2)
1 = SB400 5 = SB500
2 = TOLEDO (See Note 1) 6 = SB250/500M
3 = IQ355
NOTE 1! If you selected 2. TOLEDO for the TYPE= parameter, the following setup
menu parameters will be shown after pressing the ENTER key:
COM1 CONTINUOUS OUTPUT SELECTION
0. 8530 no CKSUM
1. SHORT no CKSUM
2. 8530 with CKSUM
3. SHORT with CKSUM
TOLEDO Format=X
With the COM1 CONTINUOUS OUTPUT SELECTION menu displayed the current
setting for the TOLEDO Format= parameter will be shown. Note that X is the
current value. If the setting displayed is acceptable, press the ENTER key to save the
new setting and return to the COM1 SETUP MENU.
Otherwise, using the numeric keys, enter the value for the TOLEDO Format and then
press the ENTER key to save the new setting and return to COM1 SETUP MENU.
Allowable values are 0, 1, 2, or 3.
NOTE 2! 9=TALLEY is displayed only if USA=NO and MODE OF OP=0, 2, 3, 4 or 5.
Refer to the ELECTRONIC TALLEY ROLL section of this manual.