7. Remove the air pressure from the reservoir by slowly loosening the fill cap
of the reservoir. Remove the drain plug from the reservoir.
8. Remove the access cover. Flush the reservoir with clean TCH fluid. Dry the
reservoir with a clean cloth.
9. Remove the suction screen. Clean the suction screen in solvent. Dry the
suction screen with compressed air. Install the suction screen.
10. Replace the hydraulic oil filter. See page 108.
11. Install the access cover with a new O-ring. Tighten the access cover bolt.
12. Clean and install the magnetic drain plug.
13. Put 16 U.S. gallons (61 litres) of new Case TCH Fluid into the reservoir.
14. Install the fill cap with a new O-ring. Turn the air pressure valve to the On
position.
15. Start the engine and operate the loader controls for three or four minutes.
Stop the engine and check for leaks. Check the oil level.
110