Emotron VS Series Quick Start Guide
- 51 -
frequency lower than lower
limit frequency
1: Run at 0 Hz would be activated
after the time delay set by b0.12
b0.12
Lower limit frequency
running time
0.06000.0s
60.0s
×
b0.13
Up to this frequency, start
frequency compensation
0.00~600.00Hz
50.00Hz
b0.14
Frequency compensation
per 50Hz
0.00~50.00Hz
0.00Hz
Group b1: Start/Stop Control
b1.00
Run command
0: Keypad control (LED off)
0
×
1: Terminal control (LED on)
2: Communication control (LED
blinking)
b1.01
Running direction
0: Forward
0
1: Reverse
b1.02
Reverse-proof action
0: Reverse enabled
0
×
1: Reverse disabled
b1.03
Dead time between
forward and reverse
0.06000.0s
0.0s
×
b1.04
Start mode
Units place: Start Mode
0:Start directly
1:Rotational speed track and
restart
00000
×
Tens place: short-circuit detection
function
0:Ungrounded short-circuit
detection
1:Grounding short-circuit
detection before the first starts
2:Grounding short-circuit
detection before each starts
Hundreds place: Speed tracking
0:Track from zero speed
1:Track from max frequency
Thousands place: Select if Jog
function takes the priority
0:Disable
1:Enable
Ten thousands place: Tracking
direction
0: Last direction when stop
1: Positive direction
2: Negative direction
b1.05
Start frequency
0.0010.00Hz
0.00Hz
×
b1.06
Startup frequency holding
time
0.0100.0s
0.0s
×
b1.07
Startup DC braking current
0.0150.0%
0.0%
×
b1.08
DC braking time at start
0.0100.0s
0.0s
×
b1.09
Speed search current
0.0180.0%
100.0%
b1.10
Speed search decel time
0.010.0s
2.0s
×
b1.11
Speed search coefficient
0.015.00
0.30
b1.12
Stop mode
0: Ramp to stop
0
×
1: Coast to stop
b1.13
Initial frequency of stop DC
braking
0.0050.00Hz
2.00Hz
×
b1.14
Stop DC braking current
0.0150.0%
0.0%
×