The machine must be stored in a secure or closed place, so as to prevent access
to unauthorized personnel.
10.5.2 - End of seasonal cycle
• The operator must:
a. Take the utmost care in carrying out the operations envisaged at the end of the daily treatments:
the cleaning of the hydraulic circuit and the main tank must be done at least twice. Check that no
product residues are left in any part of the circuit.
b. Execute the necessary maintenance and lubrication operations (see paragraph 13.10), then let
the atomizer operate for some minutes.
THE PUMP MUST NEVER RUN DRY.
00305
c. Completely drain the hydraulic circuit, paying a special attention to the centrifugal pump; in order
to completely drain the pump, remove the draining plug, which is mounted on the pump itself.
Avoid using anti-freeze solutions.
d. Check the proper operation of all parts and of the machine structure. In case of faults being
detected, request the intervention of one of our service points.
e. Keep the machine on a plane surface with a suitable consistency, in a well ventilated place,
sheltered from rain, icing and direct sun rays.
The machine must be stored in a secure or closed place, so as to prevent access