2. CAUSE: Residue of product at the entrance of the gauge
REMEDY: Clean.
3. CAUSE: Wrong positioning of the circuit-washer faucet (P15) with the circuit-washer tank empty.
REMEDY: Position the lever of the faucet correctly (P15 - pos”. 1") and fill the circuit-
washer tank.
4. CAUSE: Lack of seal of the O-Ring gasket of the pump suction connection (cone).
REMEDY: check the correct assembling and the efficiency of the O-Ring gasket, if
necessary replace the gasket.
E. FAULT: Vibrations of fan unit.
1. CAUSE: Dirty fan.
REMEDY: Wash. (It is advisable to refer a C.I.M.A. point of “Sale and Service”.
2. CAUSE: The tractor and of the atomizer PTOs are not lined up or their position determines the
overcoming of the maximum work angle of the drive cardan shaft.
REMEDY: Raise or lower the sprayer in order to realign PTO so that cardan shaft
functions correctly (see Paragraph 5.2.1).
F. FAULT: Anomalous and continuous noisiness together with vibrations of the fan group.
1. CAUSE: Breaking of the fan shaft bearings.
REMEDY: Address a C.I.M.A. point of “Sale and Service”.
2. CAUSE: Interference fan - case.
REMEDY: Address a C.I.M.A. point of “Sale and Service”.
G. FAULT: Intermittent operation of the whole distribution device
1. CAUSE: Lack of seal of the hydraulic circuit that goes from the tank (T1) suction pipes to the manual
distributor (P9) or to the electrovalves (E9)
REMEDY: Carefully inspect all the points at which suction of air can take place, including
as well those at which no liquid seepage is detected. Check the proper tightening of ring
nuts, fittings and clamps. Check the efficiency of the sealers and the integrity of the
piping. Reinstate the efficiency and replace parts that might have been found to be
defective.
H. FAULT: Intermittent spraying only on the one side of the distribution device
1. CAUSE: Faulty sealing of the hydraulic circuit going from the manual (P9) or electrical (E9)
distributor to the distribution point involved.
REMEDY: As per point G.1.
I. FAULT: No spraying action delivered: totally.
1. CAUSE: Clogging up of the grill/filter on the pump, of the pump suction inside the tank or suction
pipes of pump clogged up with deposits of hardened plant protection product.
REMEDY: Clean.