165
Update
You may configure the format of the collected data output to the host computer.
Barcodes read by the scanner will be processed in the following sequence –
1) Perform character substitution on the data scanned.
2) Add
Code ID and Length Code to the front of the data:[Code ID][Length Code][Data]
3) Process the whole data in step 2 with user formats. Data is now divided into fields by
user specified rules. Refer to
Chapter 6 Applying Formats for Data Editing.
4) Add
Prefix Code and Suffix Code before transmission:[Prefix Code][Processed
Data][Suffix Code]
IN THIS CHAPTER
5.1 Letter Case ..............................................................165
5.2 Character Substitution...............................................166
5.3 Prefix/Suffix Code .....................................................178
5.4 Code ID...................................................................179
5.5 Length Code ............................................................186
5.6 Multi-Barcode Editor..................................................194
5.7 Removal of Special Character .....................................198
5.1 LETTER CASE
By default, the alphabetics transmission is case-sensitive, meaning that the alphabet will
be transmitted according to their original case. Ignoring the original letter case, select
[Upper Case] to output data in upper case only; otherwise, select [Lower Case] to output
data in lower case only.
*Normal
Upper Case
Lower Case
Chapter 5
DEFINING OUTPUT FORMAT