5-57
Cisco 7600 Series Router Installation Guide
OL-4503-26
Chapter 5 Removal and Replacement Procedures
Removing and Replacing the Power Supply
Figure 5-61 DC-Input Wires on Left Side
Installing a PWR-2700-DC Power Supply in a Cisco 7606-S Router
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Follow these steps to install a DC-input power supply:
Step 1 Ensure that the system (earth) ground connection has been made. For ground connection installation
instructions, see the
“System Ground Connection” section on page 3-19.
Step 2 Remove the plastic bag attached to the front panel and put aside. This bag contains two plastic terminal
block barriers, two cable ties, and two cable holder covers.
Step 3 Verify that power is off to the DC circuit connected to the power supply you are installing.
Grasp both power supply handles, as shown in Figure 5-62. Slide the power supply into the power supply
bay. Make sure that the power supply is fully seated in the bay.
119950
PWR-2700-DC/6
C
H
A
S
SIS
G
R
O
U
N
D
IN
P
UT
1
O
K
48V-60V
=4
0A
IN
P
UT
2
O
K
48V
-60V
=40A
FA
N
O
K
O
U
TP
U
T
FA
IL
ALL FASTENERS M
U
ST BE FULLY ENGAGED
PRIOR TO OPERATIN
G THE POW
ER SUPPLY

Table of Contents