A-15
Cisco 7600 Series Router Installation Guide
OL-4503-26
Appendix A Technical Specifications
Regulatory Standards Compliance
Regulatory Standards Compliance
The Cisco 7600 series routers comply with the regulatory standards listed in the Regulatory Compliance
and Safety Information for the Cisco 7600 Series Routers document.
Maximum Torque 36 inch-lb.
Lugs Required Industry Standard 2-hole compression lug with holes on
5/8- inch centers
6000 W AC-input Power Supply Specification
AC-input type High-line input with power factor correction (PFC)
included
AC-input voltage rating Single-phase, 100 to 120 VAC, 200 to 240 VAC (±10% for
full range)
AC-input current rating 16 A each input
Power supply output capacity • 2900 W maximum (one input active at 220 VA C , o r
both inputs active and one input is 110
VA C a n d t h e
other is 220
VA C )
• 6000 W maximum (both inputs active at 220 VA C)
AC-input frequency 50/60 Hz (nominal) (±3% for full range)
Power supply output • 2900 W operation (one 220 VAC source or two
110
VAC sources)
–
25 A @ +3.3 V
–
12 A @ +12 V
–
63.6 A @ +42 V
• 6000 W operation (two 220 VAC sources)
–
25 A @ +3.3 V
–
12 A @ +12 V
–
137.4 A @ +42 V
KVA rating 7.2 KVA (high-line operation)
Output holdup time • 20 ms minimum
1. Power factor correction is a standard feature on all Cisco 7600 series AC-input power supplies. PFC reduces the reactive
component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current
components.
Table A-9 Power Supply Specifications (continued)
Item Specification