Replacing the Air Filter on a Cisco 7609 Router and the Cisco 7609-S Router (Optional)
Figure 5-130 Installing the Filter Assembly
Note Cisco Systems recommends that air filters be changed every three months.
Replacing the Air Filter on a Cisco 7609 Router and the Cisco
7609-S Router (Optional)
Step 1 Loosen the two fastening screws as shown in Figure 5-130 and lift the filter cage assembly off of the
support loops (see Figure 5-127).
Step 2 Remove the inner filter retainer from the filter cage assembly (see Figure 5-131) by depressing the thumb
loops and carefully sliding filter retainer outwards.