Total HNB-GW Session Thresholds
Cisco ASR 5000 Series Thresholding Configuration Guide
150
OL-25552-02
Total HNB-GW Session Thresholds
Total HNB-GW service session thresholds generate alerts or alarms based on the total number of IuH, IuCS, and IuPS
sessions facilitated by all HNB-GW services configured on the system during the specified polling interval. Thresholds
for IuH session is provided for HNB and UE seperately.
Alerts or alarms are triggered for the total of all IuH, IuCS, or IuPS sessions based on the following rules:
Enter condition: Actual total number of sessions > or = High Threshold
Clear condition: Actual total number of sessions < Low Threshold
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end of the
polling interval.
Configuring Total HNB Session Thresholds
Use the following example to configure the thresholds for total HNB sessions over IuH interface between HNB and
HNB-GW service on HNB-GW node:
configure
threshold total-hnbgw-hnb-sessions <high_thresh> [ clear <low_thresh> ]
threshold poll total-hnbgw-hnb-sessions interval <time>
threshold monitoring hnbgw-service
end
Configuring Total UE Session Thresholds
Use the following example to configure the thresholds for total UE sessions over IuH interface between HNB and HNB-
GW service on HNB-GW node:
configure
threshold total-hnbgw-ue-sessions <high_thresh> [ clear <low_thresh> ]
threshold poll total-hnbgw-ue-sessions interval <time>
threshold monitoring hnbgw-service
end
Configuring Total Iu Session Thresholds
Use the following example to configure the thresholds for total IuPS and/or IuCS sessions over Iu interface between
HNB-GW and CN node:
configure