Pull on the fan tray to slide it out of the chassis. Set
the fan tray on an antistatic surface.
3Unscrew 4 captive screws (2 at the top of the
module and 2 at the bottom of the module).
1
Hold the 2 fan tray handles with both hands.2
b) Hold both handles on the front of the fan tray with both of your hands and pull the fan tray out of the slot.
c) Set the fan tray on antistatic material or inside an antistatic bag.
Step 3
To prevent a loss of packets during operations, shut down the fabric module as follows: .
a)
Enter the poweroff module slot_number command. Input a slot number between 21 and 26 (labeled as FM 1 to FM 6
on the chassis).
b) Verify that the Fabric LED for the slot that you specified turns off.
Step 4
Remove the fabric module that you are replacing by following these steps:
Cisco Nexus 9508 NX-OS Mode Switch Hardware Installation Guide
94
Replacing or Installing Modules, Fan Trays, and Power Supplies
Removing a Fabric Module