Sometimes, the failed drive/SSD might not be reported.
Command:
1 sh raid
2 <!--NeedCopy-->
Output:
1 RAID1 status: DEGRADED
2 Drive:
3 1 ONLINE
4 Done
5 <!--NeedCopy-->
From the shell, confirm that drive 1/SSD 2 has failed, RAID status reports DEGRADED and drive 1/SSD
2 reports MISSING, or not present in the output.
1. At the Citrix ADC command prompt, switch to the shell prompt. Type: shell
2. Check the status of the RAID array. SSD2 shows missing or is not present in the output.
Command:
1 root@ns# atacontrol status ar0
2 <!--NeedCopy-->
Output:
1 ar0: ATA RAID1 status: DEGRADED
2 subdisks:
3 0 ad4 ONLINE
4 1 ---- MISSING
5 <!--NeedCopy-->
OR
1 ar0: ATA RAID1 status: DEGRADED
2 subdisks:
3 0 ad4 ONLINE
4 <!--NeedCopy-->
Note: Drive numbering changes in the shell: SSD 1 reports as drive 0 and SSD 2 as drive 1.
Perform the following steps to restore the RAID array to health by using the atacontrol utility.
1. Detach a failed drive. The failed drive is replaced with a new FRU drive.
2. Attach the FRU drive.
© 19992023 Cloud Soware Group, Inc. All rights reserved. 113

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX 8005 and is the answer not in the manual?

Citrix ADC MPX 8005 Specifications

General IconGeneral
BrandCitrix
ModelADC MPX 8005
CategoryNetwork Hardware
LanguageEnglish

Related product manuals