Citrix ADC MPX
LED Color LED Indicates
Flashing RED No power to this power supply.
Flashing GREEN Power supply is in standby mode.
GREEN Power supply is functional.
RED Power supply failure.
Flashing RED and GREEN Warning (OVP/UVP/OCP/OTP/Fan); OVP = Over
Voltage Protection; UVP = Under Voltage
Protection; OCP = Over Current Protection;
OTP = Over Temperature Protection
• Disable alarm button. Press this button to silence the power alarm when one of two power
supplies loses input power or when a power supply is malfunctioning.
• Non‑Maskable Interrupt (NMI) Button, used at the request of Technical Support to initiate a core
dump. To press this red button, which is recessed to prevent unintentional activation, use a pen,
pencil, or other pointed object. The NMI Button is also available remotely over the network in
the LOM GUI, in the Remote Control menu. For more information about the lights out manage‑
ment port of the appliance, see Citrix ADC MPX hardware‑soware compatibility matrix.
Citrix ADC MPX 15000‑50G FIPS certified appliance
September 19, 2022
The Citrix ADC MPX 15000‑50G FIPS certified appliance is a 2U appliance. This platform has two 8‑core
processors and 128 GB of memory.
Note: There are FIPS tamper seals on all sides of the appliance. Tampering with the seals breaks the
FIPS requirement.
The MPX 15000‑50G FIPS certified appliance provides a total of 12 network ports:
• Eight 10G SFP+ Ethernet Ports
• Four 50G Ethernet Ports
For information about the soware releases supported on the Citrix ADC hardware platforms, see Cit‑
rix ADC MPX hardware soware compatibility matrix.
The following figure shows the front panel of the Citrix ADC MPX 15000‑50G FIPS certified appliance.
Figure 1. Citrix ADC MPX 15000‑50G FIPS certified appliance, front panel
© 1999–2023 Cloud Soware Group, Inc. All rights reserved. 66