Citrix ADC MPX
LED Color LED Indicates
OFF No power to any power supply on the
appliance.
Flashing RED No power to this power supply.
Flashing GREEN Power supply is in standby mode.
GREEN Power supply is functional.
RED Power supply failure.
Flashing RED and GREEN Warning (OVP/UVP/OCP/OTP/Fan); OVP = Over
Voltage Protection; UVP = Under Voltage
Protection; OCP = Over Current Protection;
OTP = Over Temperature Protection
• Disable alarm button. Press this button to silence the power alarm when one of two power
supplies loses input power or when a power supply is malfunctioning.
• Non‑Maskable Interrupt (NMI) Button, used at the request of Technical Support to initiate a core
dump. To press this red button, which is recessed to prevent unintentional activation, use a pen,
pencil, or other pointed object. The NMI Button is also available remotely over the network in
the LOM GUI, in the Remote Control menu. For more information about the lights out manage‑
ment port of the appliance, see Lights out management port of the Citrix ADC MPX appliance.
Citrix ADC MPX 26000‑50S
September 19, 2022
The Citrix ADC MPX 26000‑50S appliances are 2U appliances. These appliances have two 14‑core pro‑
cessors and 256 GB of memory. The appliances have four 50G and 16 25G network ports.
For information about the soware releases supported on the Citrix ADC hardware platforms, see Cit‑
rix ADC MPX hardware soware compatibility matrix.
The following figure shows the front panel of the Citrix ADC MPX 26000‑50S appliances.
Figure 1. Citrix ADC MPX 26000‑50S, front panel
© 1999–2023 Cloud Soware Group, Inc. All rights reserved. 91