Hardware health attributes for the MPX 9100 platform
December 6, 2022
The following table lists the recommended ranges for the health attributes on the MPX 9100 platform.
Run the ipmitool sdr list command from the shell. This command lists the sensory parameters
data in detail.
Run the stat system -detail command from the CLI. This command lists a subset of the param‑
eters.
Health Attribute (shell) Health Attribute (CLI) Recommended Range
CPU Temp CPU 0 Temperature (Celsius) 10–95
PCH Temp Temperature 1 (Celsius) 10–85
System Temp Internal Temperature
(Celsius)
10–80
Peripheral Temp Temperature 0 (Celsius) 10–80
CPU_VRMIN Temp nl 10–95
VRMABCD Temp nl 10–95
VRMEFGH Temp nl 10–95
DIMMABCD Temp nl 10–80
DIMMEFGH Temp nl 10–80
Fan 1 CPU Fan 0 Speed (RPM) 1260–18060
Fan 2 CPU Fan 1 Speed (RPM) 1260–18060
Fan 3 System Fan Speed (RPM) 1260–18060
Fan 4 System Fan 1 Speed (RPM) 1260–18060
© 19992023 Cloud Soware Group, Inc. All rights reserved. 188