Citrix ADC MPX
Use the BIOS POST code to detect errors
September 19, 2022
You can read the BIOS POST code by using the LOM GUI or the shell. To interpret the BIOS Beep
codes, see https://www.supermicro.com/manuals/other/AMI_AptioV_BIOS_POST_Codes_for_SM_
Motherboards.pdf.
Read the BIOS post code by using the LOM GUI
Navigate to Miscellaneous > BIOS Post Snooping.
Read the BIOS post code by using the shell
At the prompt, type:
ipmitool raw 0x30 0x2a
Upgrade the LOM firmware on a Citrix ADC MPX appliance
October 18, 2022
Citrix has automated the upgrade of LOM firmware within Citrix ADC MPX soware. It is no longer
necessary to know your hardware platform or download any LOM firmware.
Note
This procedure requires two reboots to complete and therefore a disruption in production traic
is expected. Citrix recommends that you perform the upgrade during a maintenance window. In
a high availability setup, perform the upgrade on the secondary node to minimize disruption to
production traic. The upgrade_bmc.sh script is supported on the following platforms:
MPX 5900
MPX 8005
MPX 8900
MPX 11500
MPX 11515
MPX 14000
MPX 15000
MPX 22000
MPX 25000
© 19992023 Cloud Soware Group, Inc. All rights reserved. 174

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX 8005 and is the answer not in the manual?

Citrix ADC MPX 8005 Specifications

General IconGeneral
BrandCitrix
ModelADC MPX 8005
CategoryNetwork Hardware
LanguageEnglish

Related product manuals