EasyManuals Logo

Citrix ADC MPX 8005 User Manual

Default Icon
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #116 background imageLoading...
Page #116 background image
Citrix ADC MPX
4 2 ONLINE
5 Done
6 <!--NeedCopy-->
Example when SSD 1 fails
In the following example, SSD 1/drive 0/ata2 has failed.
1. Detach a failed drive.
1 root@ns# atacontrol detach ata2
2 <!--NeedCopy-->
2. Physically, remove SSD 1/drive 0 and replace it with a new FRU drive in slot 1.
3. Attach the FRU drive.
1 root@ns# atacontrol attach ata2
2 <!--NeedCopy-->
4. Add the FRU drive to the RAID array.
1 root@ns# atacontrol addspare ar0 ad4
2 <!--NeedCopy-->
5. Verify that the replacement drive is recognized.
1 root@ns# atacontrol status ar0
2 <!--NeedCopy-->
Output:
1 ar0: ATA RAID1 status: DEGRADED
2 subdisks:
3 0 ad4 SPARE
4 1 ad6 ONLINE
5 <!--NeedCopy-->
6. Start the rebuild process.
1 root@ns# atacontrol rebuild ar0
2 <!--NeedCopy-->
7. Monitor the rebuild process.
© 19992023 Cloud Soware Group, Inc. All rights reserved. 116