Health
attribute Unit
Lower
Non‑
Recoverable
Lower
Critical
Lower
Non‑
Critical
Upper
Non‑
Critical
Upper
Critical
Upper
Non‑
Recoverable
Peripheral
Temp
degrees C ‑9.000 ‑7.000 ‑5.000 80.000 85.000 90.000
PCH
Temp
degrees C ‑11.000 ‑8.000 ‑5.000 90.000 95.000 100.000
FPC_Temp
1
degrees C ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ 66.000 70.000 75.000
FPC_Temp
2
degrees C ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ 72.000 76.000 82.000
FPC_Temp
3
degrees C ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ 72.000 76.000 82.000
HDDBP_Temp
1
degrees C ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ 72.000 76.000 82.000
HDDBP_Temp
2
degrees C ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ 72.000 76.000 82.000
FAN 1 RPM ‑ NA ‑ 1980.000 ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑
FAN 2 RPM ‑ NA ‑ 1980.000 ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑
FAN 3 RPM ‑ NA ‑ 1980.000 ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑
FAN 4 RPM ‑ NA ‑ 1980.000 ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑
FAN 5 RPM ‑ NA ‑ 1980.000 ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑
FAN 6 RPM ‑ NA ‑ 1980.000 ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑
FAN 7 RPM ‑ NA ‑ 1980.000 ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑
FAN 8 RPM ‑ NA ‑ 1980.000 ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑
PS_1
Status
discrete ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑
PS_1 FAN RPM ‑ NA ‑ 1980.000 ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑
PS_1
Temp
degrees C ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ 72.000 76.000 82.000
PS_2
Status
discrete ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑
PS_2 FAN RPM ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑ ‑ NA ‑