ARES 506-606 - 02.2005 - GB
G.5
USING THE LINKAGE
If indicator light (5) is on, proceed as follows:
- Place the mode selector (1) in the working position (IV) ;
- Bring the selector to stop position (III). Wait for 2 seconds.
The light goes out and the linkage is operational.
MALFUNCTIONS
- The warning light (5) flashes slowly: You may continue
working. Consult your approved CLAAS agent, an incident is
affecting the force or slip controls.
- The warning light (5) flashes rapidly: Stop all activities and call
your approved CLAAS repair agent.
POSITION CONTROL
The position display is adjusted by using the keys (2) after setting
the selector (1) to the work position (IV). Press the lower key to
lower the linkage arms, the upper key to raise them. The
display (4) shows the position of the linkage arms on a scale of 0
to 100.
= bottom position
= top position
Opposite is an example of adjustment: Position 67.
382hsn02
382hsn03
382hsn04
STOP
1
III
IV
2
5