ARES 506-606 - 02.2005 - GB
G.6
FORCE CONTROL
To activate the force control, proceed as follows:
- Setting the working depth with keys (2).
- Using the keys (3) adjust the required sensitivity: These keys
act on the amplitude of the corrections made by the force
control.
- As soon as the sensitivity function is used, the adjustment
value appears on the screen (4).
- Force control sensitivity is increased by pressing the upper
key (3) and decreased by pressing the lower key (3).
- This adjustment works on a scale of 0 to 100 in steps of 10.
Example of sensitivity settings:
= linkage used in position display mode, no variation
possible.
= linkage used in force control mode, with small
variations.
= linkage used in force control mode, with large variations.
Note: When adjustment is completed the display
automatically returns to position mode.
If selector (1) is in the working position (IV), activation of the force
control (sensitivity > to 0) is shown on the display by the sign
in front of the depth instruction.
382hsn05
382hsn06
382hsn04
4 2 31IV