Chapter 5: Maintenance and troubleshooting
98-129217-D Status signalling 135
08033 Firmware image
doesn't support
antenna hardware
The antenna hardware version
is not supported by the
terminal.
Check that both the antenna
and the terminal are of the
type
SAILOR 150 FleetBroadband.
Contact your distributor if the
problem persists.
08034 Antenna failed
to exit Flash
Manager. Power
cycle needed
New firmware was successfully
uploaded to the antenna but
the antenna failed to start
normally with the new
firmware.
Reboot the terminal. Contact
your distributor if the problem
persists.
08035 Unable to open
port for HPA
burst monitoring
There was an error
communicating with the
antenna.
Reboot the terminal. Contact
your distributor if the problem
persists.
08036 Radio silence is
activated
The Radio silence function is
activated. No transmission is
allowed.
If the Radio silence function
should not be active, enter the
web interface and select
SETTINGS > Discrete I/O.
Then clear the Enabled box
for Radio silence.
08040 Excessive writes
to the flash
memory
Typically caused by wrong
configuration of APN name or
user name/password for a
profile which is set to auto-
activate.
Check that the APN name, user
name and password are set up
correctly for your profiles.
08045 Antenna -
Startup
temperature too
low
The temperature in the
antenna is too low for the
system to start up
None. If the ambient
temperature is outside the
specified limits, the antenna
may not be able to start up
properly. Refer to the
installation manual for
temperature specifications.
08046 Timeout of
startup sequence
- No antenna or
antenna
temperature too
low
The start-up sequence of the
terminal has timed out
because:
• the antenna is not
properly connected, or
• the antenna temperature
is too low to start up.
Check that the antenna cable is
properly connected at both
ends.
ID Event Text Explanation Remedy